I have a 10+ yr old Coleman spa that started acting up this summer. It was about the time that it started to get really hot here, and at the end of my water change cycle so I shut off the spa and figured that I'd worry about it when the weather started turning cooler.
Well, now the weather is turning cooler. When I turn the power back on, the display flashes 26 then 22 then 00 then OH. I know that OH is usually an over heating code and it's not over heated (the water is cold). Yesterday during the flip the breaker on and off cycle, the jets did come on for a bit and the display had all of the proper readouts. Then I flipped the breaker again and it went back to the 26 22 00 cycle. I don't know if it's time to replace the circuit board or control panel or what - any point in the right direction would be greatly appreciated.
Is there an online resource to decode the error codes? Thanks in advance. I have a 10+ yr old Coleman spa that started acting up this summer. It was about the time that it started to get really hot here, and at the end of my water change cycle so I shut off the spa and figured that I'd worry about it when the weather started turning cooler. Well, now the weather is turning cooler.
When I turn the power back on, the display flashes 26 then 22 then 00 then OH. I know that OH is usually an over heating code and it's not over heated (the water is cold). Yesterday during the flip the breaker on and off cycle, the jets did come on for a bit and the display had all of the proper readouts. Then I flipped the breaker again and it went back to the 26 22 00 cycle. I don't know if it's time to replace the circuit board or control panel or what - any point in the right direction would be greatly appreciated. Is there an online resource to decode the error codes? Thanks in advance.
The first couple of numbers is balboa id and coleman id stuff nothing to worry about. Does it ever get to were the jets start running before the OH message comes up? It does sound like a pc board because if it was a sensor it would be a SN error code. If the jets do come on before the error code is the water moving in the spa? If the pump is air locked it dry fire the heater giving you a oh message. What is the model number and year of the spa. There were a 500 series and some 100 series boards that were giving false OH error because of ozonator feedback.
If you have one try unplugging it. Here is a link to balboa error codes. Thank for the quick and informative reply. The jets only came on once and not again, I don't know if it was with or without error codes as my wife was watching the spa while I flipped the switch. She thinks that they just came on and started moving water.
It's a model 555 Tahoe - the control system is a Powerworks 514. Yes, it has an ozone system (that I think has been shot for a few years) I unplugged the white and black ozone cables from the control panel.
I pushed the hose down into the filter intake and put on the water, some bubbles came out but not a lot, I don't think that it's dry firing the heating system but I'm not 100% sure how to check that - I'd assume that if the tubes are filled that it's not. Thanks again for your help. Thank for the quick and informative reply. The jets only came on once and not again, I don't know if it was with or without error codes as my wife was watching the spa while I flipped the switch. She thinks that they just came on and started moving water. It's a model 555 Tahoe - the control system is a Powerworks 514.
Yes, it has an ozone system (that I think has been shot for a few years) I unplugged the white and black ozone cables from the control panel. I pushed the hose down into the filter intake and put on the water, some bubbles came out but not a lot, I don't think that it's dry firing the heating system but I'm not 100% sure how to check that - I'd assume that if the tubes are filled that it's not. Thanks again for your help. Someone needs to ohm out the sensors to check for obvious problems there.
If not there, probably a bad board.
CoLd = Temperature in the spa heater housing is below 40° F. Status of the heater element is unknown. The low speed pump or circ. Pump will operate continuously until the temperature rises above 45° F. OH = Over heat. The spa is at a temperature above 108°. Do not use spa when temperature is flashing or the OH message is displayed.
HLoH = Hi Limit Over Heat. Hi limit sensor is disconnected or shorted or the spa temperature is above 112° F. SEoP = Sensor open or disconnected. Heater disabled but the spa is operational. SESH = Sensor short, nonfunctional. Heater disabled but the spa is operational. PSoC = Pressure switch open with circulating pump.
PSoL = Pressure switch open with low pump. PSoH = Pressure switch open with high pump. ToE = Time out error.
Rare system error. Spa unusable.
Balboa Control Systems for Spas or Hot Tubs. Pd = Power supply, unit running on battery backup OH = Sensors reading 112-118° F. OHH = Overheat. Spa has shut down. One sensor has detected 118º F. OHS = Overheat.
Spa has shut down. One sensor has detected 110ºF. Flo = Improper flow or pressure switch malfunction Cool = Water temp 20° below set point ICE = Potential freeze condition has been detected Sn1 = Hi-limit sensor malfunction Sn3 = Temp sensor malfunction SnA = Spa is shut down. Sensor plugged into jack A is not working. Snb = Spa is shut down. Sensor plugged into jack B is not working. SnS = Sensors out of balance.
If alternating with temp, may be temporary condition. If display shows only this message (blinking) spa is shut down. HFL = Substantial difference between temperature sensors detected. Could indicate a flow problem.
Pa vm esx 6.1.0. LF = Persistent low flow problems. (Displays on the 5th occurrence of 'HFL' message with 24 hours).
Heater is shut down, but other spa functions run normally. Dr = Inadequate water detected in heater. Dry = Inadequate water detected in heater. (Displays on third occurrence of 'dr' message). Spa is shut down. Pr = When spa is first actuated, it will go into Priming Mode.
ILOC = Interlock failure - possible pump or ozone spike. (-) =Unknown water temperature. (Displays when first powered up after refill). Std = Spa operating in Standard Mode. Ecn = Spa operating in Economy Mode.
SE = Spa operating in Standard-in-Economy Mode. SL = Sleep mode Brett Aqualine Control Systems for Spas or Hot Tubs. OH = Overheat Protection (Heater is deactivated, pumps low speed is activated). Download game perang ukuran kecil windows 7. COOL = Spa water is more than 20° F cooler than the temperature set point.
FLO. = Flow Switch (heater is deactivated. Pump may also be deactivated). Hold = Panel sensors have been pressed too many times in a short period of time. HOT = Circuit Board temperature has exceeded acceptable limit. ICE = Freeze protection. No action is necessary.
I CE2 = Freeze protection. No action is necessary. PnL = Communication between the panel and circuit board is faulty. = 'Watchdog' (spa is deactivated) A problem has been detected. Sn1 = Open sensor (heater is deactivated) or Shorted sensor (spa is deactivated). Sn3 = Open or shorted sensor ( heater disabled).
FLO2 = Closed or shorted flow switch on system startup Pinnacle Control Systems for Spas or Hot Tubs. Sn1 = Nonfunctional high temperature sensor. Heater is deactivated. Sn2 = Nonfunctional temperature sensor. Heater is deactivated. FL1 = Water flow problem, inhibited or pressure switch malfunction. Check for proper spa water level and ensure pump is primed.
Check for clogged filter. FL2 = Pressure switch problem. Switch closed while pump is deactivated. COL = Cool condition. If water temperature drops 20ºF below set temperature, low speed pump and heater activates to bring temperature within 15º of set temperature.
ICE = Freeze condition. 55ºF detected. Low speed pump and heater will activate until spa reaches 65ºF. OH = High temperature condition, has reached 110ºF. Do not enter the spa. Low speed pump (and air blower if so equipped) will activate to assist in lowering temperature. = 'Watchdog'.
Water temperature has reached 118ºF. Entire system is disabled. Contact qualified service technician. Sundance Spa or Hot Tub Control Systems. These codes are related to flow issues or the pressure switch/flow switch and are by far the most common error codes. These error codes are caused by a variety of reasons.
The fundamental reason is water flow through the spa control system, if the water is not flowing at a rate to satisfy the switch, it will result in one of the error codes above. Rule number 1 is to always fill the hot tub after a drain down by placing the hose pipe in the filter housing suction fitting (remove filter) this fills the hot tub from inside to outside, rather than placing the hose pipe in tub, (this fills outside to inside) and is the primary cause of FLO errors. If however you have the fault then the first thing to do is shut the spa down, do not empty, remove the filter and make sure all the jets are open (as best you can). Then re-start the hot tub, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. If your spa is not overheating and you are getting the above error codes then a couple of things need to be investigated. Depending on where the temp sensor is mounted; usually in the wall of the spa in a sensor mount, you could have a flow issue. Shut the spa power off, remove the filter and make sure all the jets are open.
Then power the system back up, if the error code goes away, the problem was either a dirty filter (clean or replace) or too many jets were closed off. In most cases overheat issues are related to the relays on the circuit board, or the temp sensor has failed and will need to be replaced. The Spa or Hot Tub Panel Displays: HH, OOH, OH, OHS, OHt, HL, HiLi, Sn2, Sn3, tS, Ht, Blinking Lights. At least one of the sensors has detected water temperatures of 110 degrees or higher inside the heater.
These indicate that the spa has shut down due to an overheat situation: Note: Overheating may occur if the low-speed pump is set to operate for extended periods of time, or if the incorrect pump is installed. In rare cases (usually warmer climates), the circulation pump may also cause overheating. The following is a list of most probable causes of this message. Inspect these first:. Check slice or ball valves.
Make sure that they are open. Clean the filter(s), waterline skimmer and footwell suction for any blockage. In extremely hot weather, check for proper cabinet ventilation. Check for excessive filter duration.
Feb 18, 2017 - Here we are going to describe an alternative way of using the mobile terminal on iPhone, iPad without jailbreaking the same. Here in this article. Jan 23, 2012 - Make no mistake, while I love jailbreak apps and tweaks, I also have love for many. Prompt is an SSH client, and a perfect alternative to Mobile Terminal for. File system if you're jailbroken and have OpenSSH installed? Dec 25, 2017 - With MTerminal installed, users can access commands like chmod and. Then you need to drop and drag Terminal ipa to Cydia Impactor. Install jailbreak free. Dec 23, 2017 - How To Install MTerminal-Jailed App On iOS 11 [No Jailbreak Required]. You can download the IPA file of MTerminal-Jailed app from here, and then sideload it using Cydia Impactor or Xcode. Cydia Impactor: Sideload iOS Apps On Windows, Mac With Cydia Impactor Without Jailbreak.
Note: A common programming mistake is overlapping filter times that may cause the spa to filter continuously. Check the water level. Check the water temperature with an accurate temperature thermometer. Remove the spa cover and allow the water to cool. Adding cool water may be necessary. Touch any button to reset the system.
Coleman Spas Hot Tub By Maax
If the water is still hotter than the set temperature, press the blower button (if applicable) to cool the spa. If your spa is not overheating based on physical vessel temperature and you are getting the above error codes call for service.
The Spa or Hot Tub Panel Displays: HL, HFL. This indicates that a substantial difference in temperature between sensors has been detected during heating. This could indicate a flow problem. Check water level in spa. Refill, if necessary. If the water level is okay, make sure the pumps have been primed. On the fifth occurrence of the above message the panel may display -LF.
This indicates a persistent flow problem The heater is shut down while all other spa functions continue to run normally. Power on the spa must be cycled before the heater will function again. The Spa or Hot Tub Panel Displays: SN, Sn1, Sn2 Sn3, HL, E1, E3, Prh, HtS, Blinking Lights. This indicates that a sensor detects a possible freeze condition. This is a normal spa function; no further action is necessary.When either sensor reads below 40 degrees F., the system provides freeze protection. It automatically activates the pump (and the heater if necessary) to circulate the water and warm the plumbing.
The equipment stays on until the sensors detect that the spa temperature has risen to within 20 degrees of the set temperature. The other pumps and the blower will purge for 30 seconds to 2 minutes at the end of the freeze condition. If pump 1 was turned on due to this reason alone, this message will appear for up to two minutes right after very cold water is detected. Note: Internal freeze protection only functions when there is proper power running to the spa, and the control system is operational. The Spa or Hot Tub Panel Displays::IC, iCE. This indicates that the auxiliary sensor detects a possible freeze condition.
This is a normal spa function; no further action is necessary. When the auxiliary sensor reads around 40F- (actual temperature dependent on specific auxiliary sensor used), the system provides freeze protection. It automatically activates all of the pumps and the blower to circulate water and warm the plumbing. Note: This auxiliary freeze protection functions at all times, even when another fault condition has occurred and has otherwise shut the spa down.
The Spa or Hot Tub Panel Displays: dr, dry.
Comments are closed.
|